Standard Features |
- 6 Standard parameters:ECG,RESP,NIBP,SPO2,2-TEMP,PR/HR.
- 12.1"high resolution color TFT LCD display.
- Real time S-T segment analysis.
- Unique accessory management cabinet.
- 3 BP measuring methods:forward,backward,quick (15~20s).
- 7-lead ECG waveforms display in phase.
- Over 72 hours,tabular and graphic trends information easy to recall.
- Capture dynamic waveforms.
- Efficient resistance to interference of defibrillator and HF knife.
- UP to 6 hours working capacity of built-in rechargeable battery.
- Rotary knob ensuring convenient,prompt and accurate selection.
- Networking capacity.
|
Technical Specificatiion |
| Dimension and Weight |
| Dimension |
470mm x 250mm x 360mm ( outer package) |
| Gross Weight |
9KGS |
| Operation Environment |
| Temperature |
5-55 °C |
| Humidity |
30-95% |
| Power |
AC100-250V,50-60Hz |
| Scope |
adult,pediatric and neonate patients |
| Performance Specifications |
| Display |
12.1"color TFT |
| Resolution |
800x600 |
| Trace |
9 waveforms(max) |
| Sweep speed |
12.5mm/s, 25mm/s, 50mm/s |
| Indicator |
Power/battery indicator light |
| |
QRS beep and alarm sound |
| Battery |
Built-in and rechargeable,lasting for maximum 6 hours |
| Trend time |
1-72 hours |
| Alarm |
User-adjustable High Medium and Low limits 3-level Audible and visual alarm |
| Networking |
Connected to central monitoring system |
| Recorder |
Built-in thermal array
ECGPlethysmogram waveform: 2 channels
Record mode: manual,on alarm,time-defined,etc
Record width: 50mm, Print speed: 25mm/s |
| ECG |
| Lead mode |
5 -leads(RA,LA,LL,RL,V) |
| lead selection |
I,II,III,avR,avL,avF,V;MCL |
| Waveform |
7 channel |
| Gain selection |
´0.5mm/V; ´1mm/V;´2mm/V;´4mm/V |
| Sweep speed |
12.5mm/s;25mm/s;50mm/s |
| Heart Rate range |
20-250bpm |
| CMMR |
Diagnostic mode:90dB
Monitoring/operating mode: 110dB |
| Accuracy |
±2bpm |
| Resolution |
1bpm |
| Scaling signal |
1mV, ±3% |
| Alarm range |
20-250bpm |
| |
Banwidth Surgery:1~25Hz |
| |
Monitor:0.5~35Hz |
| |
Diagnostic:0.05~100Hz |
| S-T segment detection:Measurement & alam range:-2.0mV~ +2.0mV |
| NIBP |
| Method: |
Automatic oscillometric |
| Operation mode |
Manual/Automatic |
| Auto measurement time |
Adjustable(1-180min) |
| Measurement unit |
mmHg/Kpa selectable |
| Measurement types |
Forward, Backward ,Quick |
| Measurement range |
Adult: 20-270mmHg |
| |
Pediatric: 20-200mmHg |
| |
Neonate: 20-155mmHg |
| Over-pressure protection |
Double safety protection |
| Resolution |
1mmHg |
| Alarm |
Systolic,Diastolic,Mean |
| SPO2 |
| Measurement range |
0~100% |
| Resolution |
1% |
| Accuracy |
±2%(80-100%);0-60% unspecified |
| Alarm range |
0-100% |
| Respiration |
| Method |
RA-LL impedance |
| Measurement range |
0-150rpm |
| Apnea alarm |
YES |
| Temperature |
| Measurement Range |
25~45 °C |
| Resolution |
0.1 °C |
| Accuracy |
0.2 °C |
| Channel |
2 channel;T1;T2 |
| Pulse Rate |
| Range |
20-250bpm |
| Resolution |
1bpm |
| Accuracy |
2bpm |
| Alarm range |
20-250bpm |
| Standard Configuration |
ECG,NIBP,RESP,2-TEMP,SPO2,PR |
| Optional |
Thermal Recorder |
 |
Accessories: |
| NIBP Air hose |
|
NIBP Cuff for neonate |
|
Gilded 5-lead ECG Cable |
 |
|
 |
|
 |
| Gilded skin-rectal Temp Probe |
|
NIBP Air hose |
|
NIBP Cuff for neonate |
 |
|
 |
|
 |
| Skin-Rectal Temp Probe |
|
SpO2 Finger Sensor |
|
SpO2 Finger Sensor in Silica Jel |
 |
|
 |
|
 |
|
|
|