Features

  • Color TFT Display,English/Chinese Manual,4 Waveforms
  • Designed Weight-lighter to take, Built-In Battery,Continuously Monitoring
  • Parameters:ECG,Respiration,NIBP,IBP With Two Channels,Double TI,SPO2,
  • EtCO2,CO,Abnormal HB,ST Segment Ayalysis,Networking and Data Exchanging
  • Maximum 72 Hours Graphic and Tabular Trends Of All Parameters with Audioable
    And Visual Alarm
  • Built-in Recorder with numerous print Formats Selectable

Specifications

Safety
BM-9000 colorful and easy-taken multi-parameters monitor has the same safty standards which agrees with the standards of IEC60601 Groups and GB9706
Dimension and Weight
Dimension: 318mm(W)×152mm(D)×264mm(H)
Weight: 5.4kgs
Operation Environments
Power Requirements: 100-250V/AC, 50/60 Hz
Application Scope: Neonatal, pediatric, and adult patients
Performance Specifications
  • Display: Colorful TFT display
  • Resolution: 640×480
  • Language:English
  • Indicator:
      4-waveform;
      Alarm Indicator;
      AC Power Indicator;
      QRS beep and Alarm Sound
  • Interface:
      Parameter module interface;
      AC Power input socket;
      External VGA interface;
      Two display mode;
      Simulative signals output
  • Battery: Rechargable, supplying power more than 2 hours
  • Trend time: 1~72 hours
  • Alarm:
      User-adjustable high limit and low limit,
      3 Level Audible and Visual Alarming
  • Recorder: Built-in thermal printing system
  • Plethysmogram waveform: 2 channels
  • Recording modes: manual,alarm,timing
  • Printing speed: 25mm/s, 50mm/s
  • Network: Connection to center monitor system
ECG Specifications
  • 5-lead or 3-lead selectable
  • Lead Input: 5-lead: RA; LA; RL; LL; V
  • Lead mode: I; II; III; avR; avL; avF; V1-V6; CAL
  • Scanning Speed: 12.5 mm/s; 25mm/s; 50mm/s
  • Gain selection: ×0.25; ×0.5; ×1; ×2; auto
  • Heart Beating Rate: Adult: 15-300bpm, Pediatric/Neonate: 15-350bpm
  • Accuracy: ±1bpm
  • Resolution: 1bpm
  • Leakage: Less than 10μA
  • Protection:
      Isolation of Voltage AC4000V/50Hz,
      Resistance Against Defibrillator/Electronic knives and skin voltage
  • Scaling signal: 1mV/±5%
  • Band width: 0.05-100Hz
  • Alarm range: 15-350bpm
  • ST detection: YES
  • Measurement range: -2.0mV~2.0mV
  • Alarm range: -2.0mV~2.0mV
  • Analysis & Recall of Abnormal HEART BEATING: YES
  • Alarm: Audible and visual alarms/recall
Respiration Specifications
  • Mode: RA-LL impedance
  • Range: Adult: 0-120rpm; Pediatric/Neonate: 0-150rpm
  • Resolve Rate: 1rpm
  • Accuracy: ±2rpm
  • Alarm range: 0~120rpm
  • Apnea alarming: YES
NIBP Specifications
  • Measurement Method: Auto surge mode
  • Operation model: Manual/Automatic/Continuous
  • Auto measure time: selectable
  • Measurement unit: mmHg/Kpa selectable
  • Alarm: Systolic, Diastolic, Mean
  • Measurement range: Adult: 10~270mmHg;
  • Child: 10~200mmHg;
  • Neonate: 10~135mmHg
  • Over-pressure protection: yes
  • Resolution rate: 1bpm
  • Accuracy: ±1rpm
  • Pulse Alarm: 0-254bpm
Temperature Specifications
  • Measurement range: 0~50°C
  • Resolution: 0.1°C
  • Accuracy: ± 0.1°C
  • Alarm range: 0~50°C
  • Channel: 2 channel
  • Display: T1; T2; ΔT
IBP Specifications
  • Measure range: -10~300mmHg
  • Resolution: 1mmHg
  • Channel: 2
  • Alarming range: -10~300mmHg
  • Accuracy: ±2%
  • Pressure names: ART, PA, CVP, RAP, LAP, ICP
  • Pressure sensors: sensitivity:5uV/mmHg
  • Impedance range: 300~3000Ω
Cardiac Output Specifications
  • Method: thermodilution
  • Cardiac output: 0.1-20 litres/min
  • TB: 23~43'C
  • TI: 0~27'C
  • Resolution: Cardiac output: 0.1 litres/min
  • Blood temp.: ±0.1'C
  • Injection temp.:±0.1'C
  • Parameter output: cardiac output and hemodynamic calculation
SpO2 Specifications
  • Measurement range: 0~100%
  • Resolution: 1%
  • Accuracy: ±2% (70~100%); ±3%(40~69%)
  • Alarm range: 0~100%
  • Pulse Rate: Range: 0~250bpm
  • Alarming Range:0~100%
  • Pulse Range: 0~254bpm
  • Resolution: 1bpm
  • Accuracy: ±1bpm
  • Pulse Alarm: 0~254bpm
EtCO2 Specifications
  • Method: sidestream
  • Measurement range: EtCO2:0~99mmHg
  • AwRR: 0~150rpm
  • Resolution: EtCO2:1mmHg
  • Resolution rate: 1rpm
  • Accuracy:
      CO2: ±2mmHg(0~40 mmHg);
      ±5% reading(41~26 mmHg);
      ±10% reading(77~99 mmHg)
  • Respiration rate:±2 rpm
  • Alarming range: same as measurment range
Net weight : 4.0 KGS
Gross weight : 8.2 KGS
Configuration: ECG+Breathe+NIBP+SpO2+HR+2-TEMP+Battery(one piece)
Optional: Recorder, 2-IBP, CO, EtCO2(Side Stream)selectable
 
 